French Site  German Site  EU Site  Spanish Site  Other Global Sites
Search:  
Skip Navigation Links.
Home > Digital E3 Modulevel® Electronic Liquid Level Transmitter
 Digital E3 Modulevel® Electronic Liquid Level Transmitter   Printer Friendly Version
The Digital E3 is an advanced, intrinsically safe two-wire instrument utilizing simple buoyancy principle to detect and convert liquid level changes into a stable output signal. The linkage between the level sensing element and output electronics provides a simple mechanical design and construction. The vertical in-line design of the transmitter results in low instrument weight and simplified installation. The instrument comes in a variety of configurations and pressure ratings for varied applications.

The Digital E3 Modulevel has microprocessor-based electronics with HART® compatible output, in addition to the standard 4-20 mA output. E3 supports the FDT/DTM standard and a PACTware™ PC software package allows for additional configuration and trending capabilities.
Operating Principle Features Industries Options Downloads Approvals
 
Changing buoyancy forces caused by liquid level change act upon the spring supported displacer causing vertical motion of the core within a linear variable differential transformer.

As the core position changes with liquid level, voltages are induced across the secondary windings of the LVDT. These signals are processed in the electronic circuitry and used to control the current in the 4-20 mA current loop. The enclosing tube acts as a static isolation barrier between the LVDT and the process media.

 

  • Two-wire, loop-powered, transmitter for level, interface or density measurement
  • No level change needed for configuration; no field calibration necessary
  • Safety Integrity Level (SIL) value of 2, SFF value of 92.3%
  • 4-20 mA output signal
  • Two-line, 8-character LCD and 3-button keypad
  • Continuous self-test with 22 mA, 3.6 mA or hold fault indication, fully compliant with NAMUR NE 43
   

  • PACTware PC software
  • Flanged top, cage side/bottom and cage side/side designs
  • Integral or remote mount
  • Process connections from 1 1/2" to 6"
  • ANSI flanges rated from 150# RF to 2500# RF
  • FM/CSA XP, IS and NI approvals / ATEC/IEC XP and IS approvals
 
 Literature: (US English)
  Sales Literature
  Instruction Manual
  Instruction Manual
  SIL Brochure
  SIL Instruction Manual



 PACTware Software:

Magnetrol DTM software requires Microsoft .NET Framework 1.1 to be installed on your computer.

Please confirm that it is installed before installing Pactware. It is available for download at www.microsoft.com


Magnetrol DTM software requires Microsoft .NET Framework 1.1 SP1 to be installed on your computer.

Please confirm that it is installed before installing Pactware. It is available for download at www.microsoft.com


PACTware Version 4.0
File Size: 73.08 MB (76,625,279 bytes)
56K Download Time: 182.44 minute(s)
T1 Download Time: 1.60 minute(s)

Magnetrol Hart DTM Library
Eclipse 2x, 3x; Pulsar RX5; Modulevel ESII, E3; Jupiter
File Size: 38.42 MB (40,287,237 bytes)
56K Download Time: 95.92 minute(s)
T1 Download Time: 0.84 minute(s)

Magnetrol Hart DTM Library Extension
Eclipse 3x v2, 355, R82
File Size: 30.05 MB (31,510,079 bytes)
56K Download Time: 75.02 minute(s)
T1 Download Time: 0.66 minute(s)

(PACTware FAQ)
 
  • XP   

  • IS   

  • NI   
  • XP   

  • IS   
  • NI   
  • ELV   
  • XP   

  • IS   

  • NS   

  • YES   
  • XP = Explosion Proof  •  IS = Intrinsically Safe  •  NI = Non-Incendive  •  NS = Non-Sparking  •  ELV = EMC/Low Voltage