Brazil Site   French Site   German Site   EU Site   Russian Site   Other Global Sites
Contact Us | info@magnetrol.com
 
  
Image Not Recieved From Magnetrol
Product Info

Literature

Other Software

    PULSE BURST RADAR - HEAVY INDUSTRIAL APPLICATIONS
     
    Pulsar® MODEL R86 NON-CONTACT RADAR TRANSMITTER
    The Pulsar® Model R86 Radar level transmitter is the latest generation of Magnetrol loop-powered, 24 VDC, liquid level transmitters. It has a longer measurement range, circular polarization, advanced diagnostics and is easier to use than most loop-powered radar transmitters.
     
    Operating Principle
    PULSAR transmitter technology is based on pulse-burst radar technology together with equivalent time sampling circuitry. Short bursts of 26 GHz microwave energy are emitted and subsequently reflected from the liquid level surface.
     
    Applications

    Media:

    • Liquids and Slurries
    • Hydrocarbons to Water Based Media

    Vessels:

    • Process and Storage Vessels up to rated temperature and pressure
    • Pits and Sumps

    Features
    • Performance not process dependent (changing specific gravity and dielectric have no effect)
    • 26 GHz operating frequency offers superior accuracy and resolution
    • Antenna designs to +750 °F (+400 °C)
    • Range up to 130 feet (40 meters)
    • Quick connect/disconnect probe coupling allows vessel to remain sealed
    • SIL 2 capable with Safe Failure Fraction (SFF) = 93.2% (FMEDA available upon request)
    • PACTware™ PC software interface with new improved DTM.
      Options
    • HART® 7.1 and Foundation fieldbus™ digital communications
    • 316 stainless steel dual compartment enclosure
    • 1 1/2" to 4" horn antennas
    • Antenna nozzle extensions to 72" (1.8 meters)
    Approvals
    • XP=Explosion Proof
    • IS=Intrinsically Safe
    • NI=Non-Incendive
    • NS=Non-Sparking
    • ELV=EMC/Low Voltage

    • XP, IS, NI

    • ELV

    • XP, IS, NS

    • YES

    • XP, IS, NS
    Recently viewed products